Basic Info.

Model NO.
LU100
Accuracy
>±1%
Main Application
Water, Wastewater, Diesel Fuel, Steam, Compressed Air
Size
DN50-DN500
Sensor
Pulse, Electromagnetic, Ultrasonic
Application
Energy Metering
Type
Pulse, Electromagnetic, Ultrasonic
Measuring Media
Water, Steam, Compressed Air, etc
Measuring Principle
Pulse, Electromagnetic, Ultrasonic
Measurement Object
Open Channel
Certification
ISO
Transport Package
Wooden Crate and Cardboard Box
Specification
DN50-500
Trademark
Ju Xin Ao Cheng
Origin
China
Production Capacity
50000

Product Description

Integrated vortex flowmeter
Steam Integrated Meter Vortex Flow Meter
Integrated vortex flowmeter with temperature and pressure compensation, mainly used for flow measurement of industrial pipeline media fluids, such as gas, liquid, vapor and other media. Its characteristics are small pressure loss, large range, high accuracy, and almost unaffected by parameters such as fluid density, pressure, temperature, viscosity, etc. when measuring volumetric flow rate under working conditions. No movable mechanical parts, therefore high reliability and low maintenance. The instrument parameters can remain stable for a long time. This instrument uses piezoelectric stress sensors with high reliability and can operate within a temperature range of -20 ºC to+250 ºC. It has both analog standard signals and digital pulse signal outputs, making it easy to use in conjunction with digital systems such as computers. It is a relatively advanced and ideal flow rate.

As can be seen from the above equation, the pulse frequency signal output by VSF is not affected by fluid properties and composition changes, that is, the instrument coefficient is only related to the shape and size of the vortex generator and pipeline within a certain Reynolds number range. However, as a flowmeter in material balance and energy measurement, it is necessary to detect mass flow rate. At this time, the output signal of the flowmeter should simultaneously monitor volume flow rate and fluid density. Fluid properties and components still have a direct impact on flow measurement.
The vortex flowmeter is a new type of flowmeter that measures fluid flow in closed pipelines based on the Karman vortex principle. Due to its excellent medium adaptability, it can directly measure the volumetric flow rate of steam, air, gas, water, and liquid without temperature and pressure compensation. Equipped with temperature and pressure sensors, it can measure standard volumetric flow rate and mass flow rate, making it an ideal alternative to throttling flow meters.
In practical applications, the maximum flow rate is often much lower than the upper limit of the instrument, and with changes in load, the minimum flow rate is often lower than the lower limit of the instrument. The instrument is not working in its optimal working range. To solve this problem, it is usually necessary to reduce the diameter at the measuring point to increase the flow rate at the measuring point, and use smaller diameter instruments to facilitate the measurement of the instrument. However, this variable diameter method requires a straight pipe section with a length of more than 15D between the variable diameter pipe and the instrument for rectification, which makes processing and installation inconvenient. The LGZ variable diameter rectifier with a curved longitudinal section has multiple functions such as rectification, increasing flow velocity, and changing flow velocity distribution. Its structural size is small, only one-third of the inner diameter of the process pipe, and it is integrated with the vortex flowmeter. It not only does not require an additional straight pipe section, but also reduces the requirements for the straight pipe section of the process pipe, making installation very convenient.
For the convenience of use, the battery powered local display vortex flowmeter adopts low-power high-tech. It can operate continuously for more than a year with lithium battery power supply, saving the procurement and installation costs of cables and display instruments. It can display instantaneous flow, cumulative flow, etc. on site. The temperature compensated integrated vortex flowmeter also comes with a temperature sensor, which can directly measure the temperature of saturated steam and calculate the pressure, thereby displaying the mass flow rate of saturated steam. The temperature pressure compensation integrated type is equipped with temperature and pressure sensors, which can directly measure the temperature and pressure of the gas medium for gas flow measurement, thereby displaying the standard volume flow rate of the gas.
main features 
1. No movable parts, reliable operation, good performance, long service life
2. Measure the measured fluid without direct contact with the sensor, with stable performance
3. Due to less pressure loss, it has energy-saving characteristics compared to differential pressure flow meters
4. Simple and sturdy structure, easy installation, and minimal maintenance costs
Steam Integrated Meter Vortex Flow Meter
technical parameter

1. Caliber: DN15-DN200
2. Nominal pressure: 1.6MPa, 2.5MPa, 4MPa
3. Environmental temperature for use:- 25 ºC to+130 ºC- 25 ºC to+250 ºC- 25 ºC~+300 ºC
4. Accuracy: ± 1.0%
5. Power supply: Equipped with an internal 3.6V lithium battery. External power supply+24VDC ± 10%
working principle
The principle of vortex flowmeter: By setting a triangular cylindrical vortex generator in the fluid, regular vortices are alternately generated from both sides of the vortex generator, which is called Karman vortex.
The vortex flowmeter applies the principle of fluid oscillation to measure flow rate. When the fluid passes through the vortex flowmeter in the pipeline, two columns of vortices proportional to the flow velocity are alternately generated up and down behind the vortex generator in the triangular column. The release frequency of the vortices is related to the average velocity of the fluid flowing through the vortex generator and the characteristic width of the vortex generator.
The integrated vortex flowmeter is a new type of flowmeter for measuring fluid flow in closed pipelines based on the Karman vortex principle. Due to its excellent medium adaptability, it can directly measure the volumetric flow rate of steam, air, gas, water, and liquid without temperature and pressure compensation. Equipped with temperature and pressure sensors, it can measure standard volumetric flow rate and mass flow rate, making it an ideal alternative to throttling flow meters. In order to improve the high temperature resistance and vibration resistance of vortex flow meters, our company has recently developed the HLUG improved vortex flow sensor. Due to its unique structure and material selection, the sensor can be used in harsh working conditions such as high temperature (350 ºC) and strong vibration (≤ 1g). In practical applications, the maximum flow rate is often much lower than the upper limit of the instrument, and with changes in load, the minimum flow rate is often lower than the lower limit of the instrument. The instrument is not working in its optimal working range. To solve this problem, it is usually necessary to reduce the diameter at the measuring point to increase the flow rate at the measuring point, and use smaller diameter instruments to facilitate the measurement of the instrument. However, this variable diameter method requires a straight pipe section with a length of more than 15D between the variable diameter pipe and the instrument for rectification, which makes processing and installation inconvenient. Our company has developed an LGZ variable diameter rectifier with a curved longitudinal section, which has multiple functions such as rectification, increasing flow velocity, and changing flow velocity distribution. Its structural size is small, only one-third of the inner diameter of the process pipe, and it is integrated with the vortex flowmeter. It not only does not require an additional straight pipe section, but also reduces the requirements for the straight pipe section of the process pipe, making installation very convenient. For the convenience of use, the battery powered local display vortex flowmeter adopts low-power high-tech. It can operate continuously for more than a year with lithium battery power supply, saving the procurement and installation costs of cables and display instruments. It can display instantaneous flow, cumulative flow, etc. on site. The temperature compensated integrated vortex flowmeter also comes with a temperature sensor, which can directly measure the temperature of saturated steam and calculate the pressure, thereby displaying the mass flow rate of saturated steam. The temperature pressure compensation integrated type is equipped with temperature and pressure sensors, which can directly measure the temperature and pressure of the gas medium for gas flow measurement, thereby displaying the standard volume flow rate of the gas.




Product Selection
code orifice Flow range m³/h - -
LU-25 DN25 1~10(liquid) 25~60(gas)  
LU-32 DN32 1.5~18(liquid) 15~150(gas) -
LU-40 DN40 2.2~27(liquid) 22.6~150(gas) -
LU-50 DN50 4~55(liquid) 35~350(gas) -
LU-80 DN80 9~135(liquid) 90~900(gas) -
LU-100 DN100 14~200(liquid) 140~1400(gas) -
LU-150 DN150 32~480(liquid) 300~3000(gas) -
LU-200 DN200 56~800(liquid) 550~5500(gas) -
material Stainless steel 304.316 carbon steel (customizable)
Select the parameters required for the vortex flowmeter:
1. Diameter of pipeline
2. The name of the tested medium (steam should indicate whether it is saturated steam or superheated steam)
3. Working pressure of the tested medium
4. Working temperature of the tested medium
5. The working flow rate of the tested medium
Saturated vapor density, pressure, temperature
Temperature
ºC
Pressure
 kgf/m3
Density  
kg/m3
Temperature
ºC
Pressure
kgf/m3
Density
kg/m3
120 2.0245 1.121 175 9.101 4.617
122 2.1561 1.189 176 9.317 4.721
124 2.2947 1.261 177 9.538 4.829
126 2.4404 1.336 178 9.763 4.936
128 2.5935 1.414 179 9.992 5.045
130 2.7544 1.496 180 10.225 5.157
132 2.9233 1.582 181 10.462 5.271
134 3.101 1.672 182 10.703 5.388
136 3.286 1.765 183 10.950 5.507
138 3.481 1.864 184 11.201 5.627
140 3.685 1.966 185 11.456 5.750
142 3.898 2.073 186 11.715 5.875
144 4.121 2.184 187 11.979 6.002
146 4.355 2.300 188 12.248 6.131
148 4.599 2.421 189 12.522 6.262
150 4.854 2.547 190 12.800 6.394
151 4.985 2.612 191 13.083 6.532
152 5.119 2.679 192 13.371 6.671
153 5.257 2.746 193 13.664 6.812
154 5.397 2.815 194 13.962 6.954
155 5.540 2.855 195 14.265 7.097
156 5.686 2.958 196 14.573 7.246
157 5.836 3.030 197 14.866 7.396
158 5.988 3.103 198 15.204 7.547
159 6.144 3.182 199 15.528 7.704
160 6.302 3.258 200 15.857 7.862
161 6.464 3.338 201 16.192 8.026
162 6.630 3.419 202 16.532 8.183
163 6.798 3.500 203 16.877 8.354
164 6.970 3.584 204 17.228 8.518
165 7.146 3.670 205 17.585 8.688
166 7.325 3.757 206 17.948 8.865
167 7.507 3.846 207 18.316 9.042
168 7.693 3.935 208 18.690 9.225
169 7.883 4.027 209 19.070 9.407
170 8.076 4.122 210 19.456 9.588
171 8.274 4.218 211 19.848 9.775
172 8.475 4.314 212 20.246 9.970
173 8.679 4.413 213 20.651 10.170
174 8.888 4.515 214 21.061 10.360

Use case
Steam Integrated Meter Vortex Flow Meter

Steam Integrated Meter Vortex Flow Meter
Steam Integrated Meter Vortex Flow MeterSteam Integrated Meter Vortex Flow Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier